SCP Solar Controller 30-50A
Technical Data (Model:SCP-) | 024(48)30 | 024(48)40 | 024(48)50 |
Rated charge current | 30A | 40A | 50A |
Rated load current | 20A | ||
System voltage | 24V/48V automatic identification | ||
Input of the photovoltaic module | < 50V; *4/48V | ||
720Wp; *2/48V | 960Wp; *2/48V | 1200Wp; *2/48V 2/48V | |
No-load loss | ≤ 15mA | ||
Voltage drop of the charge circuit | ≤ 0.26V | ||
Voltage drop of the discharge circuit | ≤ 0.15V | ||
Overvoltage protection | 17V; *2/24V; *4/48V | ||
Voltage of boosting charge | 14.6V; *2/24V; *4/48V (hold time: 30min) (called upon overdischarge only) | ||
Voltage of direct charge | 14.4V; *2/24V; *4/48V (hold time: 30min) | ||
Voltage of floating charge | 13.6V; *2/24V; *4/48V (hold time: operation will begin upon the charge recovery voltage) | ||
Charge recovery voltage | 13.2V; *2/24V; *4/48V | ||
Undervoltage voltage | 12.0V; *2/24V; *4/48V | ||
Overdischarge recovery voltage | 12.6V; *2/24V;*4/48V | ||
Control mode | PWM (pulse width modulation) | ||
Operating temperature | Industrial level: -35℃~+55℃ | ||
External dimensions D*W*H (mm) | 155*145*67 | ||
Net weight | 0.9kg |
Main features
Excellent performance because of MCU control and intelligent optimized SOC design;
Longer batteres lives because of functons of overcharge function and overdischarge protection for batteries;
Full automatic control such as electronic short circuit protection, overload protection and unique reserve connection prevention;
Visualization of operation status of the equipment through simple LED indicators and nixie tubes and one-button setting;
An industrial chip provided for all control to enable equipment to operate in a cold, hot or humid condition;
Crystal oscillator is used for timing control, featuring accurate control and having multi-stage single-interval fixed-time setting and independently settable multi-stage dual-interval foxed-time setting.